array(3) {
["data"] => array(20) {
[0] => array(11) {
["tagname"] => string(27) "低压配电柜安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1594865492"
["tagid"] => int(716874)
["id"] => string(6) "716874"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503934914560006)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/716874"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/716874"
}
[1] => array(11) {
["tagname"] => string(27) "低压配电柜安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1594865492"
["tagid"] => int(717529)
["id"] => string(6) "717529"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503934932385820)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/717529"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/717529"
}
[2] => array(11) {
["tagname"] => string(36) "照明母线的安装规范是什么"
["inlink"] => int(0)
["addtime"] => string(10) "1599530139"
["tagid"] => int(1180017)
["id"] => string(7) "1180017"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503950339112973)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1180017"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1180017"
}
[3] => array(11) {
["tagname"] => string(21) "安装规范是什么"
["inlink"] => int(0)
["addtime"] => string(10) "1600481200"
["tagid"] => int(1446655)
["id"] => string(7) "1446655"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503960161124353)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1446655"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1446655"
}
[4] => array(11) {
["tagname"] => string(36) "水暖安装的规范步骤是什么"
["inlink"] => int(0)
["addtime"] => string(10) "1600842360"
["tagid"] => int(1834384)
["id"] => string(7) "1834384"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503974784565248)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1834384"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1834384"
}
[5] => array(11) {
["tagname"] => string(33) "空调风口安装规范是什么"
["inlink"] => int(0)
["addtime"] => string(10) "1600842360"
["tagid"] => int(1835172)
["id"] => string(7) "1835172"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503974807633935)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1835172"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1835172"
}
[6] => array(11) {
["tagname"] => string(15) "安装须规范"
["inlink"] => int(0)
["addtime"] => string(10) "1600481739"
["tagid"] => int(1605088)
["id"] => string(7) "1605088"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503966446288923)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1605088"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1605088"
}
[7] => array(11) {
["tagname"] => string(15) "附安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1600481566"
["tagid"] => int(1528875)
["id"] => string(7) "1528875"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503962935656469)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1528875"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1528875"
}
[8] => array(11) {
["tagname"] => string(18) "地暖安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593420953"
["tagid"] => int(26303)
["id"] => string(5) "26303"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503909459329042)
["pageurl"] => string(34) "//www.sheji456.com/ask/tlist/26303"
["m_pageurl"] => string(32) "//m.sheji456.com/ask/tlist/26303"
}
[9] => array(11) {
["tagname"] => string(18) "水表安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574362"
["tagid"] => int(116117)
["id"] => string(6) "116117"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503913228959750)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/116117"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/116117"
}
[10] => array(11) {
["tagname"] => string(18) "弱电安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574413"
["tagid"] => int(124186)
["id"] => string(6) "124186"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503913469083660)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/124186"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/124186"
}
[11] => array(11) {
["tagname"] => string(18) "水管安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574704"
["tagid"] => int(162746)
["id"] => string(6) "162746"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503914630905859)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/162746"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/162746"
}
[12] => array(11) {
["tagname"] => string(18) "地漏安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574704"
["tagid"] => int(166976)
["id"] => string(6) "166976"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503914928701459)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/166976"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/166976"
}
[13] => array(11) {
["tagname"] => string(18) "电线安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574776"
["tagid"] => int(205113)
["id"] => string(6) "205113"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503916058017811)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/205113"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/205113"
}
[14] => array(11) {
["tagname"] => string(18) "消防安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593574946"
["tagid"] => int(228249)
["id"] => string(6) "228249"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503918076526618)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/228249"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/228249"
}
[15] => array(11) {
["tagname"] => string(18) "插座安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593575176"
["tagid"] => int(279457)
["id"] => string(6) "279457"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503919731179531)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/279457"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/279457"
}
[16] => array(11) {
["tagname"] => string(18) "暖气安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1593575176"
["tagid"] => int(290198)
["id"] => string(6) "290198"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503920041558016)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/290198"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/290198"
}
[17] => array(11) {
["tagname"] => string(18) "煤气安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1598842100"
["tagid"] => int(788165)
["id"] => string(6) "788165"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503937008566307)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/788165"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/788165"
}
[18] => array(11) {
["tagname"] => string(18) "马桶安装规范"
["inlink"] => int(0)
["addtime"] => string(10) "1598842100"
["tagid"] => int(796349)
["id"] => string(6) "796349"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503937240301568)
["pageurl"] => string(35) "//www.sheji456.com/ask/tlist/796349"
["m_pageurl"] => string(33) "//m.sheji456.com/ask/tlist/796349"
}
[19] => array(11) {
["tagname"] => string(30) "下水管安装规范是什么"
["inlink"] => int(0)
["addtime"] => string(10) "1600480755"
["tagid"] => int(1389931)
["id"] => string(7) "1389931"
["depart"] => string(1) "0"
["updatetime"] => int(0)
["status"] => int(99)
["_version_"] => int(1703503958198190101)
["pageurl"] => string(36) "//www.sheji456.com/ask/tlist/1389931"
["m_pageurl"] => string(34) "//m.sheji456.com/ask/tlist/1389931"
}
}
["counts"] => int(1157677)
["pagecount"] => float(57884)
}

10秒装修报价 装修要花多少钱?获得精准报价,省钱30%
168211
元
材料费:77201元
人工费:86544元
设计费:1760元
质检费:2706元
低压配电箱的安装位置要避免阳光直射,避免溅水,避免潮气,并且前方有充裕的*作空间。应定期对柜内设备进行清扫,检查接线端子,检查各开关,接触器是否良好,内部有无过热现象,应定期检查配电柜密封性能,防止小动物进入或者内部结露。对于湿气大的地区还要配备驱潮器、干燥器等。应检查安装位置是否牢固,不得偏斜晃动。 (1)设备要求 1)柜(盘)本体外观检查应无损伤及变形,油漆完整无损。柜(盘)内部检查:电器装置及元件、绝缘瓷件齐全,无损伤、裂纹等缺陷。 2)安装前应核对配电箱编号是否与安装位置相符,按设计图纸检查其箱号、箱内回路号。箱门接地应采用软铜编织线,专用接线端子。箱内接线应整齐,满足设计要求及验收规范(GB50303-2002)的规定。 (2)作业条件配电箱安装场所土建应具备内粉刷完成、门窗已装好的基本条件。预埋管道及预埋件均应清理好;场地具备运输条件,保持道路平整畅通。 (3)配电箱*:根据设计要求现场确定配电箱位置以及现场实际设备安装情况,按照箱的外形尺寸进行弹线*。 (4)基础型钢安装 1)按图纸要求预制*基础型钢架,并做好防腐处理,按施工图纸所标位置,将预制好的基础型钢架放在预留铁件上,找平、找正后将基础型钢架、预埋铁件、垫片用电焊焊牢。最终基础型钢顶部宜高出抹平地面10mm。 2)基础型钢接地:基础型钢安装完毕后,应将接地线与基础型钢的两端焊牢,焊接面为扁钢宽度的二倍,然后与柜接地排可靠连接。并做好防腐处理。 (5)配电柜(盘)安装 1)柜(盘)安装:应按施工图的布置,将配电柜按照顺序逐一就位在基础型钢上。单独柜(盘)进行柜面和侧面的垂直度的调整可用加垫铁的方法解决,但不可超过三片,并焊接牢固。成列柜(盘)各台就位后,应对柜的水平度及盘面偏差进行调整,应调整到符合施工规范的规定。 2)挂墙式的配电箱可采用膨胀螺栓固定在墙上,但空心砖或砌块墙上要预埋燕尾螺栓或采用对拉螺栓进行固定。 3)安装配电箱应预埋套箱,安装后面板应与墙面平。 4)柜(盘)调整结束后,应用螺栓将柜体与基础型钢进行紧固。 5)柜(盘)接地:每台柜(盘)单独与基础型钢连接,可采用铜线将柜内PE排与接地螺栓可靠联结,并必须加弹簧垫圈进行防松处理。每扇柜门应分别用铜编织线与PE排可靠联结。 6)柜(盘)顶与母线进行连接,注意应采用母线配套扳手按照要求进行紧固,接触面应涂中性凡士林。柜间母排连接时应注意母排是否距离其他器件或壳体太近,并注意相位正确。 7)控制回路检查:应检查线路是否因运输等因素而松脱,并逐一进行紧固,电器元件是否损坏。原则上柜(盘)控制线路在出厂时就进行了校验,不应对柜内线路私自进行调整,发现问题应与供应商联系。 8)控制线校线后,将每根芯线煨成圆圈,用镀锌螺丝、眼圈、弹簧垫连接在每个端子板上。端子板每侧一般一个端子压一根线,最多不能超过两根,并且两根线间加眼圈。多股线应涮锡,不准有断股。 (6)柜(盘)试验调整 1)高压试验应由当地供电部门许可的试验单位进行。试验标准符合*规范、当地供电部门的规定及产品技术*要求。 2)试验内容:高压柜框架、母线、避雷器、高压瓷瓶、电压互感器、电流互感器、各类开关等。 3)调整内容:过流继电器调整,时间继电器、信号继电器调整以及机械连锁调整。 4)二次控制小线调整及模拟试验,将所有的接线端子螺丝再紧一次。 5)绝缘测试:用500V绝缘电阻测试仪器在端子板处测试每条回路的电阻,电阻必须大于0.5MΩ。 6)二次小线回路如有晶体管,集成电路、*元件时,应使用万用表测试回路是否接通。 7)接通临时的控制电源和*作电源;将柜(盘)内的控制、*作电源回路熔断器上端相线拆掉,接上临时电源。 8)模拟试验:按图纸要求,分别模拟试验控制、连锁、*作、继电保护和信号动作,正确无误,灵敏可靠。 9)拆除临时电源,将被拆除的电源线复位。 (7)送电运行的条件 1)安装作业应全部完毕,质量检查部门检查全部合格。试验项目全部合格,并有试验报告单。 2)试验用的的验电器、绝缘靴、绝缘手套、临时接地编织铜线、绝缘胶垫、粉沫灭火器等应备齐。 3)检查母线、设备上有无遗留下的杂物。 4)做好试运行的组织工作,明确试运行指挥人,*作人和监护人。 5)清扫设备及变配电室、控制室的灰尘。用吸尘器清扫电器、仪表元件。 6)继电保护动作灵敏可靠,控制、连锁、信号等动作准确无误。 (8)送电 1)由供电部门检查合格后,将电源送进建筑物内,经过验电、校相无误。 2)由安装单位合进线柜开关,检查PT柜上电压表三相是否电压正常。 3)合变压器柜开关,检查变压器是否有电。4)合低压柜进线开关,查看电压表三相是否电压正常。 5)按以上顺序依次送电。 6)在低压联络柜内,在开关的上下侧(开关未合状态)进行同相校核。用电压表或万用表电压档500V,用表的网个测针,分别接触两路的同相,此时电压表无读数,表示两路电同一相。用同样方法,检查其他两相。 7)验收:送电空载运行24h,无异常现象、办理验收手续,交建设单位使用。同时提交变更洽商记录、产品合格证、说明书、试验报告单等技术*。
只要注意绝缘、走线整齐美观就好,先做好盘柜基础,焊接底座,将柜子挪上底座后,并柜、连接母排,按图纸要求放线,接线,通电前的测量与实验,空载通电试验,带载就可以了~
低压配电箱的安装位置要避免阳光直射,避免溅水,避免潮气,并且前方有充裕的*作空间。应定期对柜内设备进行清扫,检查接线端子,检查各开关,接触器是否良好,内部有无过热现象,应定期检查配电柜密封性能,防止小动物进入或者内部结露。对于湿气大的地区还要配备驱潮器、干燥器等。应检查安装位置是否牢固,不得偏斜晃动。
您好 ,我帮您看过了哦,只是我不好复制的,因为太多了,所以建议您自己到网上搜索一下哦,网上都有步骤教您怎么安装的哦,上面讲的很详细的,希望我的*有帮到您,祝生活愉快!
高低压配电柜安装规范 1.安装前对准备工作的检查 在安装前,监理工程师及甲方工程师要检查进场道路是否畅通,必要时要求要求总包单位修建简易运输通道与各安装点连接,施工场地布置应满足安全文明施工的要求。同时还应检查安装单位的施工机具安排状况,督促安装单位对施工机具进行检查,确保状态良好。高压设备到达现场前,配电室、地沟、基础槽钢应已完全竣工 1)、配电室 配电室:配电室施工前,要将建配电室所需的详细图纸交予施工方(合同签订后2周内,重点要落实客户对图纸的位置、内容、完成时间确认),并且在配电室建设过程中,我方或协作单位的技术人员要在现场监督,避免施工错误。(配电室建设大约需2周左右) 2)、地基:槽钢安放位置要与配电室预留的设备风道相对应,设备离墙的最小距离要明确(距离太近,设备的柜门打不开)。(槽钢焊接大约需2天,我方技术人员必须到场指导) 设备到达现场: 3)、若配电室、地基若未建好,设备要有存放位置(要防雨或提供必要的防雨材料)。 2.安装 2.1各配电房门窗须严密,房内清洁。 阅读会员限时特惠 7大会员特权立即尝鲜2.2配电盘安装稳固。盘内设备与各构件间连接牢固。 2.3盘、柜的接地应牢固良好。装有电器的可开启的盘、柜门,应以软导线与接地的金属构架可靠地连接。 2.4端子箱安装应牢固,封闭良好,安装位置应便于检查,成列安装时,应排列整齐。 2.5配电盘内布线要横平竖直,螺丝不能有松动,线头接触良好。 2.6盘内各元件固定可靠无松动,触头无氧化,*刺。 2.7二次回路的连接件均应采用铜质制品。结线的具体要求: 2.7.1电气回路的连接(螺栓连接、插接、焊接等)应牢固可靠。 2.7.2电缆芯线和所配导线的端部均应标明其回路编号;编号应正确,字迹清晰且不易脱色。 2.7.3配线整齐、清晰、美观;导线绝缘良好,无损伤。 2.7.4盘、柜内的导线不应有接头。 2.7.5每个端子板的每侧接线一般为一根,不得超过两根。 2.8 400伏及以下的二次回路的带电体之间或带电体与接地间,其电气间隙不应小于4毫米。漏电距离不应小于6毫米。 2.9使用于连接可动部位(门上电器、控制台板等)的导线尚应符合下列要求: 2.9.1应采用多股软导线,敷设时应有适当余度。 2.9.2线束应有加强绝缘层(如外套塑料管等)。 2.9.3与电器连接时,端部应绞紧,不得松散,断股。 2.9.4在可动部位两端,应用卡子固定。 2.10引进盘、柜内的控制电缆及其芯线应符合下列要求: 2.10.1引进盘、柜的电缆应排列整齐,避免交叉,并应固定牢固,不使所接的端子板受到机械应力。 2.10.2铠装电缆的钢带不应进入盘、柜内;铠装钢带切断处的端部应扎紧; 2.10.3用于晶体管保护、控制等逻辑回路的控制电缆,当采用屏蔽电缆时,其屏蔽层应予接地;如不采用屏蔽电缆时,则基备用芯线应有一根接地; 2.10.4橡胶绝缘芯线应外套绝缘管保护; 2.10.5盘、柜内的电缆芯线,应接垂直或水平有规律地配置,不得任意歪斜交叉连接;备用芯应留有适当余度。 2.11在绝缘导线可能遭到油类污蚀的地方,应采用耐油的绝缘导线,或采取防油措施。 2.12配电装置的安全技术要求: 2.12.1两路及以上电源供电时,各路电源主进与联络开关之间应装设联锁装置(受供电部门调度者除外)。 2.12.2 10千伏室内成套设备的隔离开关和相应的断路器之间应装有联锁装置。 2.12.3 配电装置的相色排列应符合列规定: (1)同一配电装置内各回路相色排列应尽量一致。 (2)硬母线应涂色,其色别为:a 相**;b相绿色;c 相红色;零线黑色。 (3)软母线应标明相别。 (4)配电装置间隔内的导线应留有悬挂临时接地线的位置,此处不应涂相色漆。 2.13端子板的安装应符合下列要求: 2.13.1端子板应无损坏,固定牢靠,绝缘良好。 2.13.2端子板应便于更换且接线方便。 2.13.3回路电压超过400伏者,端子板应有足够的绝缘并涂以红色标志。 3检查 3.1巡检 3.1.1高低压配电室的通风、照明及安全防火装置是否正常。 3.1.2配电盘门严密无损坏现象,配电盘内清洁,无尘土。 3.1.3站内所有配电屏必须挂牌,以示*告。 3.1.4信号装置回路的信号灯、电铃、事故电钟等应显示准确,工作可靠。 3.1.5配电柜内电机的电压、电流是否正常(不超出额定值的5%)。 3.1.6母线和各接点是否有过热现象,示温蜡片是否熔化,绝缘胶木有无烧坏现象。 3.1.7开关柜中各电气元件在运行中有无异常气味和声响。 3.1.8注油设备的油位是否正常,油色是否变深,有无渗漏油现象。 3.1.9仪表、信号、指示灯等指示是否正确,继电保护压板位置是否正确。 3.1.10继电器及直流设备运行是否良好。 3.1.11接地和接零装置的连接线有无松脱和断线。 3.1.12瓷瓶、绝缘套管、穿墙套管等绝缘是否清洁,有无破损裂纹及放电痕迹。 3.1.13断路器和隔离开关的机械联锁是否灵活可靠,如采用电磁联锁装置,则需通电检查电磁锁动作是否灵活,开闭是否准确。 3.2月检 每月对电机、配电柜的各*作部分和电气部分做一次全面检查、磁力起动器动合闸试验、继电器的灵敏度试验。 3.3年检 每三年对电机、配电柜做一次继电试验,由供电人员检定。 3.4检修及保养 3.4.1检修及保养每月进行一次。 3.4.1停电检修线路,必须先挂牌,后作业,以示*告。 3.4.2电机、电缆、配电屏必须接地良好,接地电阻不应大于4欧。 3.4.3电机测量直流阻抗,作交流耐压试验。电流互感器和电压互感器作耐压试验和变流比试验。 3.4.5电缆作直流耐压泄漏试验;继电器检修,重新整定。 3.4.6油开关作解体检查修理、调整、紧固;避雷器作耐压试验。
Q/ZXJZ J621—2004 1 低压成套配电柜及动力开关柜(盘)、照明配电箱施工工艺标准 1 适用范围 本工艺标准适用于我总公司所有在施的公共与民用建筑施工。 2 引用标准 GB50303-2002 (2002.4) 建筑电气施工质量验收规范 GB50300-2001 建筑工程施工质量验收统一标准 GB50150 电气装置安装工程电气设备交接试验标准 GB50254-96 (1996.12) 电气装置安装工程施工及验收规范 GB50255-96 (1996.12) 电气装置安装工程施工及验收规范 GB50256-96 (1996.12) 电气装置安装工程施工及验收规范 GB50257-96 (1996.12) 电气装置安装工程施工及验收规范 DBJ 01-26-96 (1996.8) 建筑安装分项工程施工工艺规范 电气装置安装工程施工及验收规范汇编 (1996) 北京地区电气规程汇编 (2002.12) 3 施工准备: 3.1 设备及材料要求 3.1.1 设备及材料均符合国标或部颁发的现行的技术标准,符合设计要求;并有3C认证和产品合格证及随带安装、使用、维修和试验要求等技术文件;有生产许可证和安全认证标志,进口产品应提供商检证明和中文的质量证明文件、规格、型号、性能检测报告及中文的安装、使用、维修和试验要求等技术文件。设备有铭牌,并注明厂家名称,附件、备件完好、齐全,接线无脱落脱焊,涂层完整,无明显碰撞凹陷。 3.1.2 铁制配电箱、柜体为镀锌板,并应具有一定的机械强度,配电箱体二层板厚度不小于1.5毫米镀锌铁板。塑料配电箱体有一定的机械强度,周边平整无损伤,二层板厚度不小于8毫米。木制配电箱体应刷防腐、防火涂料,木制板面厚度不小于20毫米。 3.1.3 柜、箱内的保护导体应有*露的连接外部保护导体的端子,当设计无要求时,柜箱内保护导体的最小截面积SP不应小于表1规定。 3.1.4 柜、箱内低压电器组合应符合下列规定: 3.1.4.1 发热元件安装在散热良好的位置; 3.1.4.2 熔断器的熔体规格、自动开关的整定值符合设计要求; 3.1.4.3 切换压板接触良好,相邻压板间有安全距离,切换时不触及相邻的压板; 3.1.4.4 信号回路的信号灯、按钮、光字牌、电铃、电笛、事故电钟等动作和信号显示准确; 3.1.4.5 外壳需接地(PE)和接零(PEN)的,连接可靠; 3.1.4.6 端子排安装牢固,端子有序号,强、弱电端子隔离布置,端子规格与芯线截面积大小适配。 3.1.5 柜、箱内配线: 3.1.5.1 电流回路采用额定电压不低于750V、芯线截面不小于2.5mm2的铜芯绝缘电线或电缆; 3.1.5.2 除*元件回路或类似回路外,其它回路的电线应采用额定电压不低于750V、芯线截面不小于1.5mm2的铜芯绝缘电线或电缆;